본문 바로가기 주메뉴 바로가기

NGS(Next Generation Sequencing)

1. NGS Systems [MGI]

NGS Systems [MGI]
Product Model DNBSEQ-T20x2 DNBSEQ-T7 DNBSEQ-G400 DNBSEQ-G400*
For HotMps Only
DNBSEQ-G50 DNBSEQ-G99
Dimensions 4200mm*4800mm
*2000mm
1656mm*903mm
*1815mm
1086mm*756mm
*710mm
1086mm*756mm
*710mm
654mm*489mm*
654mm*489mm*
654mm*489mm*
*640mm
Applications Ultra-high=depth
Whole Geome
Sequencing
Deep Whole Genome
Sequencing
WGS, WES,
Trascriptiome
sequencing, etc.
WGS, WES,
Transcriptome
sequencing, etc.
Small whole Genome
sequencing, targeted
panels, low-pass whole
genome sequencing
Targeted oncology
panel sequencing,
infectious disease
sequecing, 16S
metagenomic
Sequencing
Max. Flow Cell/Run 6 4 2 2 1 2
Flow Cell Type Slide FC FCS&FCL FCL FCS&FCL FC
Lane/Flow Cell++ 1 Lane 1 Lane 4 Lanes or 2 Lanes 4 Lane 1 Lane 1 Lane
Operation Mode Ultra-high throughput High and Ultra-high
Throunghput
Medium and High
Throungput
Medium and High
Throughput
Medium Throughput Low and Medium
Low and Medium
Max.Throunghput
/Run
~72Tb 7Tb 1400Gb 720Gb 150Gb 96GB
Effective Reads/
Flow Cell
35B(PE 100) 5800M 300M, 550M,
1500M~1800M
1500M~1800M 100M, 500M 80M
Average Run
Time
60hrs~80hrs 16hrs~24hrs FCS : 13hrs~37hrs
FCL : 14hrs~109hrs
15.5hrs~50.5hrs 9hrs~40hrs 5hrs~30hrs
Min.Read
Length
PE100 PE100 SE50 SE50 SE50 SE100
Max. Read
Length
PE150 PE150 PE300 PE100 PE150 PE300

2. NGS Library Automations

1) Revvity

Revvity
Zephyr G3 NGS[IQ]
Sciclone G3 NGSx
Sciclone G3 NGSx IQ
System 96 pipetting head, 12 deck positions
[+27(3stackers)]
96 pipetting head, 40 deck positions
(24 for tip boxes, 16WS)
96 pipetting head, 48 deck positions
(21WS, 27 Tip Box(3 stackers), PCR sys.
Sample Capacity 8 to 48/96 samples per run 3 to 5 batches each with 8 to 96 samples
per week(depending on application)
3 to 5 batches each with 8 to 96 samples
per week(192 samples depending on
application)
Key Applications
  • -Library preparation(DNA, RNA)
  • - Targeted resequencing Post PCR
  • - SPRl bead purification
  • - Nomalization&qPCR setup
  • -Library preparation(DNA, RNA)
  • - Sequence capture
  • -Normalization&pooling
  • - Custom protocols
  • -Library preparation(DNA, RNA)
  • - Sequence capture
  • -Normalization&pooling
  • - Custom protocols
  • - Nonstop Process for 96 samples
Ideally for... HT sample preparation (e.g. For
NextSeq2000)
[Full Automation System
(Included PCR, Tip_Stacker(3X9),
Twister ARM)]
HT sample preparation (e.g. For
NextSeq2000, NovaSeq6000)
HT sample preparation (e.g. For
NextSeq2000, NovaSeq6000)
Full Automation System
(Included PCR, Tip_Stacker(3X9),
Twister ARM)

2)MGI

MGI
MGISP-100
MGISP-960
MGISP-SMART8
Size 780mmX725mmX777mm 1240mmX740mmX1110mm 1410mmX799mmX970mm
Weight 130kg 280kg 220kg
Pipette Type Fixed 8 channel Fixed 96 channel Independent 8-channel pipette
Throughput Sandard : 16 samples/run Sandard : 96 samples/run Sandard : 8~48/96
Pipette Range 2㎕~200㎕ 1㎕~200㎕ 1㎕~1000㎕
Pipette Accuracy 2㎕<±10%
200㎕<±1%
2㎕<±10%
200㎕<±1%
1㎕<±10%; 200㎕<±2%;
1000㎕<±1%
Pipette CV 2㎕<5%
200㎕:<1%
2㎕<5%
200㎕:<1%
1㎕:CV<8%;
200㎕:CV<1%; 10001㎕:CV<1%

3. NGS Library Kit